Electric Motor Wire Marking & Connections
For specific Leeson Motor Connections go to their website and input the Leeson catalog # in the "review" box, you will find connection data, dimensions, name plate data, etc. www.leeson.com
Single Phase Connections: (Three Phase--see below) Single Voltage:
Rotation |
L1 |
L2 |
CCW |
1,8 |
4,5 |
CW |
1,5 |
4,8 |
Dual Voltage: (Main Winding Only)
Voltage |
Rotation |
L1 |
L2 |
Join |
High |
CCW |
1 |
4,5 |
2&3&8 |
|
CW |
1 |
4,8 |
2&3&5 |
Low |
CCW |
1,3,8 |
2,4,5 |
------- |
|
CW |
1,3,5 |
2,4,8 |
------- |
Dual Voltage: (Main & Auxiliary Winding)
Voltage |
Rotation |
L1 |
L2 |
Join |
High |
CCW |
1,8 |
4,5 |
2&3,6&7 |
|
CW |
1,5 |
4,8 |
2&3,6&7 |
Low |
CCW |
1,3,6,8 |
2,4,5,7 |
--------- |
|
CW |
1,3,5,7 |
2,4,6,8 |
--------- |
Single Phase Terminal Markings Identified By Color: (NEMA Standards) 1-Blue 5-Black P1-No color assigned 2-White 6-No color assigned P2-Brown 3-Orange 7-No color assigned 4-Yellow 8-Red
Three Phase Connections:
Part Winding Start: 6 Leads NEMA Nomenclature: WYE or Delta Connected
|
T1 |
T2 |
T3 |
T7 |
T8 |
T9 |
Motor Leads |
1 |
2 |
3 |
7 |
8 |
9 |
9 Leads NEMA Nomenclature WYE Connected (low voltage only)
|
T1 |
T2 |
T3 |
T7 |
T8 |
T9 |
Together |
Motor Leads |
1 |
2 |
3 |
7 |
8 |
9 |
4&5&6 |
12 Leads NEMA & IEC Nomenclature Single Voltage or Low Voltage of Dual-Voltage Motors
|
T1 |
T2 |
T3 |
T7 |
T8 |
T9 |
NEMA |
1,6 |
2,4 |
3,5 |
7,12 |
8,10 |
9,11 |
IEC |
1 |
2 |
3 |
7 |
8 |
9 |
Three Phase Motors-Single Speed
Nema Nomenclature--6 Leads:
Single Voltage--External WYE Connection
L1 |
L2 |
L3 |
Join |
1 |
2 |
3 |
4&5&6 |
Single Voltage--External Delta Connection
Single Voltage WYE-Delta Connections
Operating mode |
Connection |
L1 |
L2 |
L3 |
Join |
Start |
WYE |
1 |
2 |
3 |
4&5&6 |
Run |
Delta |
1,6 |
2,4 |
3,5 |
------- |
Dual Voltage WYE-Delta Connections
Voltage |
Connection |
L1 |
L2 |
L3 |
Join |
High |
WYE |
1 |
2 |
3 |
4&5&6 |
Low |
Delta |
1,6 |
2,4 |
3,5 |
------- |
NEMA Nomenclature--9 Leads: Dual Voltage WYE-Connected
Voltage |
L1 |
L2 |
L3 |
Join |
High |
1 |
2 |
3 |
4&7, 5&8, 6&9 |
Low |
1,7 |
2,8 |
3,9 |
4&5&6 |
Dual Voltage Delta-Connected
Voltage |
L1 |
L2 |
L3 |
Join |
High |
1 |
2 |
3 |
4&7, 5&8,6&9 |
Low |
1,6,7 |
2,4,8 |
3,5,9 |
------------ |
NEMA Nomenclature--12 Leads: Dual Voltage--External WYE Connection
Voltage |
L1 |
L2 |
L3 |
Join |
High |
1 |
2 |
3 |
4&7, 5&8, 6&9, 10&11&12 |
Low |
1,7 |
2,8 |
3,9 |
4&5&6, 10&11&12 |
Dual Voltage WYE-Connected Start Delta-Connected Run
Voltage |
Conn. |
L1 |
L2 |
L3 |
Join |
High |
WYE |
1 |
2 |
3 |
4&7, 5&8, 6&9, 10&11&12 |
|
Delta |
1,12 |
2,10 |
3,11 |
4&7, 5&8, 6&9 |
Low |
WYE |
1,7 |
2,8 |
3,9 |
4&5&6, 10&11&12 |
|
Delta |
1,6,7,12 |
2,4,8,10 |
3,5,9,11 |
------------ |
IEC Nomenclature--6 & 12 Leads: Single Voltage WYE-Delta Connections Single Voltage WYE-Delta Connections
oper- mode |
Conn. |
L1 |
L2 |
L3 |
Join |
Start |
WYE |
U1 |
V1 |
W1 |
U2&V2&W2 |
Run |
Delta |
U1,W2 |
V1,U2 |
W1,V2 |
-------------- |
Dual Voltage WYE-Delta Connections
Volt |
Conn. |
L1 |
L2 |
L3 |
Join |
High |
WYE |
U 1 |
V1 |
W1 |
U2&V2&W2 |
Low |
Delta |
U1,W2 |
V1,U2 |
W1,V2 |
-------------- |
Dual Voltage WYE-Connected Start Delta-Connected Run
Volt |
Conn. |
L1 |
L2 |
L3 |
Join |
High |
WYE |
U 1 |
V1 |
W1 |
U2&U5,V2&V5, W2&W5,U6&V6&W6 |
|
Delta |
U1,W6 |
V1,U6 |
W1,V6 |
U2&U5,V2&V5, W2&W5 |
LOW |
WYE |
U1,U5 |
V1,V5 |
W1,W5 |
U2&V2&W2, U6&V6&W6 |
|
Delta |
U1,U5, W2,W6 |
V1,V5 U2,U6 |
W1,W5 V2,V6 |
----------------------------- |
NEMA Nomenclature--6 Leads: Constant Torque Connection (Low-speed HP is half of high-speed HP)
Speed |
L1 |
L2 |
L3 |
|
Typical Connection |
High |
6 |
4 |
5 |
1&2&3Join |
2 WYE |
Low |
1 |
2 |
3 |
4-5-6 Open |
1 Delta |
Variable Torque Connection (Low-speed HP is 1/4 of high-speed HP)
Speed |
L1 |
L2 |
L3 |
|
Typical Connection |
High |
6 |
4 |
5 |
1&2&3Join |
2 WYE |
Low |
1 |
2 |
3 |
4-5-6 Open |
1 WYE |
Constant Horsepower Connection (HP is the same at both speeds)
Speed |
L1 |
L2 |
L3 |
|
Typical Connection |
High |
6 |
4 |
5 |
1-2-3 Open |
1 Delta |
Low |
1 |
2 |
3 |
4&5&6-Join |
2 WYE |
IEC Nomenclature--6 Leads: Constant Torque Connection
Speed |
L1 |
L2 |
L3 |
|
Typical Connection |
High |
2W |
2U |
2V |
1U&1V&1W--JOIN |
2 WYE |
Low |
1U |
1V |
1W |
2U-2V-2W OPEN |
1 Delta |
Variable Torque Connection
Speed |
L1 |
L2 |
L3 |
|
Typical Connection |
High |
2W |
2U |
2V |
1U&1V&1W--JOIN |
2 WYE |
Low |
1U |
1V |
1W |
2U-2V-2W OPEN |
1 WYE |
|